• small datalogger MicroLog MP mod. A with three soil water content sensors CS616 – fixed configuration
  • time-domain measurement method
  • 30 cm long sensor rods
  • low maintenance, easy installation and set-up
  • large logging capacity and long battery lifetime
  • infrared wireless data access
  • Mini32 software support

Specification

SWC measuring range 0% VWC to saturation
SWC accuracy ± 2.5% VWC
SWC resolution 0.1% VWC
Internal temperature range  –40 to 60 °C
Internal temperature accuracy ± 0.2 °C
Measuring intervals 1 min to 4 hrs
Memory capacity with measuring interval 1 hour ca 5 years
Battery life with measuring interval 1 hour ca 2 years
Protection rating IP68
Operating environment temperature  –40 to 60 °C
Operating environment humidity 0 to 100%

Mini32 software

E MS Micro Log T 3- 5
  • graphically oriented software intended for work with long time series
  • fast calculation of hourly, daily, montly values
  • fast brief statistics
  • built-in efficient commands for summation and min-max-average calculation

Download

documentdocument 2 Datasheet

Accessories

Compatible sensors