New Mini32 version (402.53) is available.

It supports new Minikin V2i (two external voltage channels) and three-channel event recorder MicroLog ER3i. It introduces a file name prefix that helps to distinguish between files from different sites for instance.
More: Automatically searches for available COM ports. Switching between COM ports directly from the main screen. Comfortable sequential download from more loggers located in neighborhood. Stem increment data can be graphically shifted up in order to get continuous line despite of mechanical resetting the sensor that reached the maximal range. Introducing a “Restore” button helpful in case of accidentally graphical operation (erase, fill-in). Optional line thickness in graphics. Individual setting of connection following records with line by variables coming from different files with different time span between records. Opening another file in a separate window in time synchronized mode. Time correction without initializing the system – supported by new loggers only. Automatic calculation according to a CLC file located in working directory (filename must correspond to the datalogger device code – DC. CLC).

GOOD NEWS! Decagon has accepted the problem with 10HS

soil sensors caused probably by a defective electronic part. The company promised to replace all faulty sensors with new units. All our customers are encouraged to ask for sensor replacement.

Dobrá zpráva pro uživatele čidel 10HS

Decagon uznal výrobní vadu jedné série čidel a souhlasí s výměnou za nové kusy. Prosíme naše zákazníky u nichž se vada čidel projevila aby nás kontaktovali. Pokud jsou čidla umístěná ve větších hloubkách, pošleme čidla náhradní předem.

ATTENTION: We have new fax number: +420 513 034 071

Decagon 10HS sensors problem.

Recently, we register more and more complains of our customers for sensor malfunction. At the moment we are discussing with Czech local distributor if there is not a manufacturing issue. All users are kindly asked to check the data set thoroughly. In case of strange patterns please remove the wrong sensors and send is to us as soon as possible. Please note that since those sensors are often connected to the powering voltage together with next sensors, the other sensors might be influenced by increased 10HS power consumption, too.

Problém s čidly půdní vlhkosti Decagon 10HS.

V současné době registrujeme více stížností našich zákazníku ohledně vadné funkce 10HS, která se projeví pár měsíců po instalaci. Vstoupili jsme v jednání s dovozcem ohledně podezření na výrobní vadu. Prosíme naše zákazníky, aby si důkladně prohlédli záznamy s těchto čidel a v případě podezření ze špatné funkce čidla vykopali a poslali k nám na reklamaci. POZOR: V mnoha případech jsou 10HS napájena společně s dalšími čidly (typicky teplota a vlhkost vzduchu) a porucha 10HS, spojená obvykle se zvýšeným proudovým odběrem ze zdroje, ovlivní funkci všech takových čidel.

New Mini32 version 402.35 available.

New options: File history, Subgraph, Czech and English hints

Note for DRL26 users:

Units with serial number lower than 8008280 could have a problem with moisture inside. Concerned users are recommended to return dendrometers to manufacturer for free improvement of sealing. Upgrade is easy to recognize after the stainless steel ring over the white lid.

Windows© 7 users have probably problem to display Mini32 help file.

It is caused by an system error. Please follow Microfsoft advice.

Uživatelé Windows© 7 pravděpodobně nemohou číst nápovědu k programu Mini32.

Jde o systémovou chybu, kterou lze odstranit dle pokynů firmy Microsoft.

Once again to time shift to 2041. 

After Mini32 upgrade please convert HEX to DCV format file again in order to repair the time scale.

Ještě poznámka k časovému posunu do roku 2041. 

Pro opravu časové osy je nutno provést novou konverzi z HEX do DCV formátu!

Minikin RTH Multisensor is comming.

Global radiadion/Air Temperature/Air Humidity in one radiation shield. Available in April.

MicroLog T3 has been put on the market.

Watertight datalogger with three soil temperature sensors. Infrared data access. Designed for long time burying in the soil.

New version of Mini32 is available.

It solves the problem with accidental time shift and offers the EdgeBox firmware upgrade.

Nová verze Mini32 je už dostupná.

Řeší problém posunu času u EdgeBox a MicroLog SP3 dataloggerů a nabízí opravu firmware. SP3 budou našim zákazníkům vyměněny protože u nich uživatelská změna firmware není možná.

POZOR! U některých dataloggerů řady EdgeBox a MicroLog

došlo 1.1.2010 nekontrolovaně k posunu času o několik let dopředu. Problém řešíme úpravou PC software Mini32. Ztráta dat nehrozí.

ATTENTION! A firmware error has occurred by EdgeBox and MicroLog dataloggers.

The real time clock has shifted to the year 2043. Please be patient – we are working on this problem in order to solve it in Mini32 software. Data will be fully recovered!!!

NEW! Datalogger EdgeBox 12 available.

12 Voltage channels, two counters. Special excitation output activated in averaging intervals only.

This output is intended for powering sensors measuring slowly changing variables or for power demanding sensors. Typical example is measurement of solar radiation and soil moisture with the same datalogger. Radiation sensor output has to be measured more often (each minute) than soil moisture which changes more slowly. It also saves the batteries when soil sensors are not uselessly powered each measuring intervals but just in times of averaging and storing to datalogger memory.

NEW! MicroLog SP3 for three soil water potential sensors

gypsum blocks or Watermark is already available.

Infrared data access without the opening the enclosure. Ready for burying into the soil. Datalogger body temperature is measured for the soil temperature estimation.

Please keep your Mini32 up to date!

The software supports all our older systems but an obsolete Mini32 version cannot handle newer products!

Repair

Please add a brief history of the product sent to us for repair for inspection. It helps us to find the problem efficiently.